You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 3 Current »

RELEASED  

Random control frequency in Self-service POS

(RTP-28182)

The random control mechanism in EG POS may now be configured to occur more frequently in periods. A new button in POS Monitor (not available in Monitor App) may toggle this functionality On and Off. A message is broadcasted to all surveillance cash registers to synchronize the status. The increased frequency of the random control is configured in a separate parameter, the same way as "ordinary" random control is configured in the existing one.     

POS Configuration

New parameter:

'ShopAndGoControlPercentageIncreased' (default empty) - Must be configured for increased automatically triggering due to number of items, subtotal in the receipt etc. 

NB!

If this parameter is not configured, and someone activates 'more often control' by button in POS Monitor, no random control will trigger at all! Hence, configure this parameter with at least identical values as 'ShopAndGoControlPercentage', to secure random control works as before.

Relevant existing parameters:

'ShopAndGoControlPercentage' (default empty) - Must be configured for automatically triggering due to number of items, subtotal in the receipt etc.

'ShopAndGoActivateLindbakControl' (default 'False') - Must be activated to trigger random control automatically (does not affect 'C' button in monitor).

Improvements POS 

AreaDescription 
Flight integration

 Age and quota control age info is improved now (RTP-31059)

New date info:

  • Under 18: After <today's date -18 years>
  • 18-20: <today's date +1 day -20 years> - <today's date day -18 years>
  • Over 20: Before <today's date +1 day -20 years>

Fuel Integration

Manual Fueling (RTP-31152)

A function to sell the fuel manually (MANUAL_FUELING) has been implemented.

Self-service

Early inactivity warning in self-service mode (RTP-31243)

The early warning for inactivity in self-service mode displays correctly to customers. This feature helps notify users of inactivity to ensure a smooth and efficient self-service experience.

POS Configuration:

Relevant existing parameters:

'SnGIdleTimerFirstTimeout' (default '0' (not in use)) - Number of milliseconds after which an early warning message is shown to customer, telling that POS is in use.

'ShopAndGoCheckoutIdleTimeout' (default '60000' (60 seconds)) - Number of milliseconds after which an inactivity warning message is shown to customer, and the countdown to cancelling the receipt will start.

'ShopAndGoIdleCountdownDuration' (default '10000' (10 seconds)) - Number of milliseconds the inactivity warning message (countdown) will last.

PLU items sent to Datema for control (RTP-30893)

PLU items are sent to Datema for control, reversing previous changes. This update aligns with recent changes in the control user interface, making the control routine smoother for staff and preventing unnecessary deviations.

Translation

Missing text in Finish resource file (RTP-29162)

Some needed texts in the resource file for Finland is inserted.

  • No labels