You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 8 Current »

List view of checkpoints with various sort, filter and search options, as well as the option to export to Excel. 

Asset search field: Search for asset number and asset name. Shows checkpoints connected to a selected asset and subordinate assets. Check off for search performed in the selected structure only. 

  

Status light bulbs for due checkpoints: 

  • Green light bulb: From Date before today’s date 

  • Yellow light bulb: From Date = today’s date until To Date 

  • Red light bulb: Day after To Date 

  • Blue light bulb: Checkpoint has been marked as complete. 


Checkpoint status information: 

Indicates checkpoints generated on the checklist. Please note: via this button a checkpoint can also be set to completed. For further details please also see the chapter ‘5.1.3.1 Checkpoint’.

Indicates checkpoints that are not within From/To Date on the checklist. 

  Indicates checkpoints not associated with a checklist. 


Checkpoint status (filters): 

  • "Generated - Unfinished items": Checkpoints with green, yellow or red light bulb. This is also indicated with an arrow with a black background. 

  • Generated - Finished items: Checkpoints with blue light bulb. This is also indicated with an arrow with a black background. 

  • Not generated - not executed items: Checkpoints with a green light bulb that are not within the From/To Date of the checklist. This is also indicated with an arrow without a black background. 

  • Checkpoints not attached to any PMI: These are also indicated by the fact that they have an arrow neither with or without a black background in the list view. 


Note: If the list is filtered on a specific checklist, you can change the point's position number in the checklist. NB! Change only one pos.nr. at a time (between each save) for repositioning to work. If there are many changes, export the list to Excel and use import studio in UPDATE mode to set new positions.


Graphical display of measuring point values

If the checkpoint list is filtered on 'Measuring' in the 'Type' filter, and one or more checkpoints are marked in the list, this button will appear in the bottom right corner, if you press the 'Save (Marked)' button. You will now get a graphical display of the reading values. Can also be accessed via the 'Readings' menu 5.4.0 Readings.